CK2091 Magnetron
General performance and mechanical performance |
Parameter |
Unit |
Weight |
1.6 |
kg |
Hight |
≤210 |
mm |
Installation location |
Axial vertical installation |
|
Core column cooling |
Forced air cooling 300 |
L/min |
Anode cooling |
Water cooling 8 |
L/min |
Output terminal cooling |
Forced air cooling 500 |
L/min |
Service life |
≥500 |
h |
Electrical parameters Rated value |
Rated value |
Unit |
Filament voltage |
8 |
V |
Filament current |
29 |
A |
Frequency |
2450 |
MHz |
Output Power |
15 |
KW |
Anode voltage |
12.6 |
KV |
Anode current |
1.8 |
A |
Magnetic field |
1450 |
GS |
Peak anode current |
40 |
A |
Electric parameter limit value |
Min. |
Max. |
Unit |
Filament surge current |
|
89 |
A |
Cathode warm-up time |
60 |
|
S |
Anode current |
|
1.9 |
A |
Anode input power |
|
24 |
KW |
Load standing wave voltage ratio |
|
2.5 |
|
Anode temperature |
|
100 |
℃ |
Anode cooling water flow |
8 |
|
L/min |
Anode outlet water temperature |
|
50 |
℃ |
Cathode terminal temperature |
|
150 |
℃ |
Cathode cooling air volume |
300 |
|
L/min |
Electromagnet shell temperature |
|
60 |
℃ |
Output air volume |
500 |
|
L/min |
The main parameters4:Typical working state
Filament voltage |
5 |
V |
Filament current |
29 |
A |
Anode voltage |
12.5 |
KV |
Anode current |
1.8 |
A |
Magnetic field current |
3.2 |
A |
Output Power |
15 |
KW |